Compact in size and lightweight, SuperGen x ray generator series offers high quality, cost effective, radiographic capabilities with powerefficiency and high reliability for veterinary, Universal single phase mains input power, powered by a standard wall receptacle of any country.
SuperGen X- ray Generator
Overview
Compact in size and lightweight, SuperGen x ray generator series offers high quality, cost effective, radiographic capabilities with power efficiency and high reliability for veterinary, Universal single phase mains input power, powered by a standard wall receptacle of any country.
The 220V high frequency generator is incorporated directly into the X-ray table, using minimal space.
We have much experience on customized HF Generator to meet diversified customer demands.
Features
- Excellent Performance and Stability.
- Full Auto mA calibration, kV calibration, kV & mA feedback waveform display and analysis.
- Adaptive mA calibration automatically compensates for filament aging.
- Easy parameter setting and firmware upgrade.
- System diagnosis, error log and statistical data display.
- Remote diagnosis via Internet reduces service cost and system downtime.
- Real-time monitoring self-diagnosis and error code display.
- Tube anode HU display & protection, tube overload & housing over heat protect.
SuperGen X- ray Generator |
||
Generator Type | SuperGen 22R | SuperGen 32R |
Output Power | 22kW | 32kW |
Nominal Mains Voltage | 220VAC ±10%, 50/60Hz 1 phase | 220VAC ±10%, 50/60Hz 1 phase |
380VAC ±10%, 50/60Hz 3 phase | ||
Output Frequency | 50kHz | 50kHz |
kV Range | 40kV-150kV, 1kV step | 40kV-150kV, 1kV step |
Accuracy of kV | ±5% | ±5% |
mA range | 10-200mA | 10-320mA |
10-500mA(380V) | ||
Accuracy of mA | ±20% | ±20% |
ms range | 1-8000ms | 1-8000ms |
Accuracy of ms | ±(5% + 1ms) | ±(5% + 1ms) |
mAs | 0.2-80mAs | 0.2-100mAs |
0.2-630mAs(380V) | ||
Accuracy of mAs | ±(5% + 0.2mAs) | ±(5% + 0.2mAs) |
Rotor Control | Low speed | Low speed |
Auxiliary Interface | Wall bucky, table bucky, free | Wall bucky, table bucky, free |
cassette, DR auxiliary | cassette, DR auxiliary | |
Exposure Technique | kV-mA (AEC) | kV-mA (AEC) |
Selection | kV-mAs | kV-mAs |
kV-mA-ms | kV-mA-ms | |
Automatical Programs Radiograph | User programmable maximum APR data is 2000 | User programmable maximum APR data is 2000 |
DAP(Option) | N/A | Yes |
AEC(Option) | Field: 3 field | Field: 3 field |
Film screen: high, middle, low (200~1200) | Film screen: high, middle, low (200~1200) | |
Density: -8~+8 | Density: -8~+8 | |
System Interface | AEC chamber number: 3 | AEC chamber number: 3 |
AEC chamber power supply:+/-15V, 500V | AEC chamber power supply: +/-15V,500V | |
Aux Power(Option) | 24VAC/6.3A | 24VAC/6.3A |
Aux Capacitor(Option) | Yes | Yes |
Communication Interface | RS-232 | RS-232 |
Dimension | 420X600X400mm ±10mm | 420X600X400mm ±10mm |
Weight | 55kg±5kg | 60kg±5kg |
Console(Option) | Console(Calibration), | Console(Calibration), |
Mini Console | Mini Console |